PRINCIPLES OF MAGNETIC RESONANCE TECHNOLOGY IN MEDICAL IMAGING OF NON IONIZATION IMAGES

Ioannis Vlachos

Abstract


The X-ray tube is one of the most important components in any X-ray system. In the beginning, physicists and physicians used gas ion tubes. The so-called Coolidge tube applied a high vacuum and is still used today. Medical examinations have required continuously improved designs of X-ray tubes (smaller focal spots at a higher output). The principle of the Goetze line focus is still applied in any diagnostic X-ray tube. Different anode materials and the rotating anode contributed to an increased output and reduced exposure time. Bearings needed special attention. Spiral groove bearings are the most advanced design today. The heat storage capacity of the anode and the tube housing assembly influences examination time and patient throughput. Cardiac imaging required less motion blurring in cine film images and increasing radiation exposure in interventional procedures called for measures to reduce dose. Protection against radiation and electric shock has always been a concern of design engineers. Focal spot sizes dedicated to specific applications and heat management within the total tube housing assembly will be future issues. Even with the event of ultrasound and MR technology, X-ray procedures will still be applied for diagnostic and interventional purposes.

Keywords


Education, X-ray tube, X-rays, Non Ionization Radiation , X- ray Radiologists & Radioprotection Protection, Medical Instruments Technologists, X-ray Departments Nurses, X-ray Departments Doctors, Medical Imaging

Full Text:

PDF

References


Rabi, Ι.Ι.; Zacharias, J.R.; Millman, S.; Kusch, Ρ. (1938). «Μια νέα μέθοδος μέτρησης της πυρηνικής μαγνητικής ροπής». Physical Review 53 (4): 318–327.doi:10.1103/PhysRev.53.318. PMID 9981980. Bibcode: 1938PhRv...53..318R.

Bibliography of I. Rabi στο Nobelprize.org. https://www.nobelprize.org/prizes/physics/1944/rabi/facts/ (last access 2022)

Filler, Aaron (2009). «The history, development and impact of Computational Imaging in Neurological Diagnosis and Neurosurgery The history, development and impact of Computational Imaging in Neurological Diagnosis and Neurosurgery: CT, MRI και DTI». Nature Precedings.doi:10.1038/npre.2009.3267.5.

Nobel Prize in Physics 1952 at Nobelprize.org. https://www.nobelprize.org/prizes/physics/1952/summary/ (last access 2022)

Principle of Shielding and Deshielding | NMRCentral.com

Quantum automaton and quantum computation (see also references therein)

Karatopis A., Kandarakis I., Magnetic Resonance Imaging, Arakynthos University Press, 2007, ISBN 978-960-91034-9-7


Refbacks

  • There are currently no refbacks.