The X-ray tube is one of the most important components in any X-ray system. In the beginning, physicists and physicians used gas ion tubes. The so-called Coolidge tube applied a high vacuum and is still used today. Medical examinations have required continuously improved designs of X-ray tubes (smaller focal spots at a higher output). The principle of the Goetze line focus is still applied in any diagnostic X-ray tube. Different anode materials and the rotating anode contributed to an increased output and reduced exposure time. Bearings needed special attention. Spiral groove bearings are the most advanced design today. The heat storage capacity of the anode and the tube housing assembly influences examination time and patient throughput. Cardiac imaging required less motion blurring in cine film images and increasing radiation exposure in interventional procedures calling for measures to reduce dose. Protection against radiation and electric shock has always been a concern of design engineers. Focal spot sizes dedicated to specific applications and heat management within the total tube housing assembly will be future issues. Even in the event of ultrasound and MR technology, X-ray procedures will still be applied for diagnostic and interventional purposes.

Keywords


Education, X-ray tube, X-rays, Ionization (Ionization) Radiation , X- ray Radiologists & Radioprotection Protection, Medical Instruments Technologists, X-ray Departments Nurses, X-ray Department Doctors

Full Text:

PDF PDF

References


Hellenic Atomic Energy Committee (https://eeae.gr/) (last access 2021)

G. Economou: Notes of TEI of Athens, School: Health and Welfare Professions, Department: Radiology - Radiology.

I. Kandarakis: Physical and Technological Principles of Radiology. 'GREEK' Publications.

I. Vlachos. M.Sc. Study of space radiation in conventional radiology units. Department of Medicine, Department of Physics. University of Patras. Patras 2007

Vlachos I, Kandarakis I. and Panayiotakis G. Secondary radiation mapping. PIJR, Indian Journal Of Research. (October 2021). Print Issn No. 2250-1991. doi: 10.36106/paripex

Rovithis Michael, Anatomy Notes .I.

Malatara Agriculture, Introduction to Radiology. Radiophysicist, PhD, General Hospital of Patras, Department of Medicine.

G. Panayiotakis. Physics of Radiodiagnostics. Course notes, Department of Physics. University of Patras.

A. Galanopoulou, G. Economou: Notes of TEI of Athens, School: Health and Welfare Professions, Department: Radiology - Radiology.

Br. J Radiolo. 1997 Nov ;70 Spect No: S1-9. doi: 10.1259/bjr.1997.0002. X-ray tubes--continuous innovative technology.

Leonardo Abbene, Angelo La Manna, Francesco Fauci, Gaetano Gerardi, Simone Stumbo, Giuseppe Raso. X-ray spectroscopy and dosimetry with a portable CdTe device. Nuclear Instruments and Methods in Physics Research A 571 (2007), 373–377. www.sciencedirect.com. Elsevier www.elsevier.com/locate/nima. Available on line 13 November 2006. Nuclear Instruments & Methods In Physics Research Section A.

G MCVEY, D Phil and H WEATHERBURN, PhD. A study of scatter in diagnostic X-ray rooms. The British Journal of Radiology, 77 (2004), 28–38 E 2004, The British Institute of Radiology DOI: 10.1259/bjr/93969091